Oil Immersed Transformer

10 kV Three Phase Oil-Immersed Distribution Transformer

A three-phase oil-immersed platform for 10 kV distribution in commercial, industrial, residential and renewable-energy projects.

Capacity range
Up to 5,000 kVA
Voltage class
10 kV
10 kV Three Phase Oil-Immersed Distribution Transformer
07Product image for reference. Final layout varies with the selected configuration.

Overview

Explore the configuration.

Start with the network supply, required secondary voltage and connected load. For a replacement, a readable nameplate and site photos help identify the electrical duty and installation interfaces without guessing the model.

10 kV Three Phase Oil-Immersed Distribution Transformer
Select 1, 2 or 3 to explore the configuration. Markers indicate discussion areas, not an assembly drawing.

Connections

Start with the network voltages and connection arrangement. Review the terminal or cable interfaces against your system and project drawing.

Primary Voltage
6 / 6.6 / 10 / 10.5 / 11 / 13.8 kV
Secondary Voltage
220 / 230 / 240 / 380 / 400 / 415 / 480 / 600 / 690 V
View the related specifications

Insulation & cooling

Review the insulating liquid and cooling arrangement for the duty. Confirm the compatible options, installation clearances and liquid containment in the project design.

Cooling
ONAN / ONAF / KNAN / KNAF
Insulation class
Class A (105°C, oil-immersed)
View the related specifications

Installation

Plan the footprint, access and cable routes using the approved outline drawing. Share the installation environment so the mechanical interfaces can be reviewed.

IP class
IP54 (outdoor enclosure)
Environment
Outdoor, -25°C to +40°C
View the related specifications

Specifications

Ratings & configuration

Listed options describe the product range. Final ratings, compatible combinations and performance are confirmed in the approved project datasheet.

Capacity rangeUp to 5,000 kVA
Voltage class10 kV
Frequency50 / 60 Hz
Tap Range±2 × 2.5%
Vector GroupDyn11
Primary Voltage6 / 6.6 / 10 / 10.5 / 11 / 13.8 kV
Secondary Voltage220 / 230 / 240 / 380 / 400 / 415 / 480 / 600 / 690 V
CoolingONAN / ONAF / KNAN / KNAF
IP classIP54 (outdoor enclosure)
Oil typeMineral oil / FR3 / Silicone
EnvironmentOutdoor, -25°C to +40°C
Core materialCold-rolled grain-oriented silicon steel
Insulation classClass A (105°C, oil-immersed)

Define the details together.

  • Electrical duty
    Primary and secondary voltage, capacity, frequency, load profile and tap requirements.
  • Installation & transport
    Outdoor conditions, containment, access, transport dimensions and the equipment interfaces.
  • Acceptance scope
    Required standard, loss and noise limits, inspection points and the reports to be reviewed.

Compare the range

Standards & compliance
GB / IEC / IEEE / UL / CE / ASTA
Applicable standards and required certificates or test reports must be agreed for the specific project. A standard listed here is not a certification claim.

Listed options describe the product range. Final ratings, compatible combinations and performance are confirmed in the approved project datasheet.

Manufacturing

A closer look at our factory.

Explore our manufacturing and test equipment. The production route and acceptance tests are agreed for each configuration.

Horizontal winding machine 1
01

Horizontal winding machine 1

Vapour-phase drying plant 1
02

Vapour-phase drying plant 1

Intelligent insulating-oil treatment system 1
03

Intelligent insulating-oil treatment system 1

Images from our factory gallery. Equipment shown does not imply every product uses the same manufacturing process.

Explore the Factory

Related orders

Recent related orders

Selected S11-M distribution transformer orders. Ask us to review a comparable configuration for your project.

Recent related orders
Order dateConfigurationVoltage ratioQuantityEnquire similar
Order record2,000 kVAS11-M-2000 · Dyn1110 / 0.4 kV1 unitEnquire similar
Order record250 kVAS11-M-250 · Dyn1110 / 0.4 kV1 unitEnquire similar
Order record500 kVAS11-M-500 · Dyn1110 / 0.4 kV1 unitEnquire similar

Contract/order records, not stock or delivery confirmations. Specifications vary by project.

Questions

Before you enquire

Talk to an engineer
Can the order examples on this page be used as my specification?

They show selected recorded order configurations. They do not establish delivery, installation results or suitability for another project. Confirm your own voltage ratio, capacity, vector group, impedance and accessories separately.

What do you need to prepare a quotation?

Start with your email and a short description. Tell us what you want to power, replace or purchase. You can send known ratings or a drawing, but you do not need to know every specification.

How are lead time, warranty and delivery agreed?

These are defined in the project quotation after reviewing the technical scope, quantity, destination and document requirements.

Talk to an engineer

Tell us what you need.

A short description is enough. We’ll help clarify the specifications.

10 kV Three Phase Oil-Immersed Distribution Transformer

Add company, location or drawings (optional)
PDF, DWG, DXF · up to 3 files, 20 MB each

Completing security check…

Protected by Cloudflare Turnstile

Our engineers will review your inquiry and follow up with next steps.