10 kV Three Phase Oil-Immersed Distribution Transformer
Commercial buildings, hospitals, airports, factories, residential areas, renewable energy projects, data centers.
- Voltage class
- 10 kV
- Capacity range
- Up to 5,000 kVA
PRODUCT FAMILY / 8 LISTED PLATFORMS
Compare distribution, substation and higher-voltage platforms. Start with the supply voltage, load and site conditions to shortlist a configuration.
Compare published ranges. Confirm the final configuration with our engineers.

CHOOSE BY PROJECT
Choose the closest product route, then compare the electrical scope and installation requirements.

Start with the incoming supply, secondary service and load. Compare the listed 10 kV and 20 kV platforms.
Explore this range 02
Review the transformer and adjoining equipment as one interface, using the single-line diagram and layout.
Explore this range 03
Review the 35 kV, 66 kV and 110 kV platforms against grid interfaces, capacity and project duty.
Explore this range 04
Explore the 230 kV and 500 kV platforms. Capacity, insulation and transport scope are defined per project.
Explore this rangeRANGE AT A GLANCE
Listed options describe the product range. Final ratings, compatible combinations and performance are confirmed in the approved project datasheet.
On smaller screens, swipe the table to compare all columns.
| Product platform | Voltage class | Capacity range | Frequency | Cooling | Details |
|---|---|---|---|---|---|
| 10 kV Three Phase Oil-Immersed Distribution Transformer | 10 kV | Up to 5,000 kVA | 50 / 60 Hz | ONAN / ONAF / KNAN / KNAF | View product — 10 kV Three Phase Oil-Immersed Distribution Transformer |
| 20 kV Three Phase Oil-Immersed Distribution Transformer | 20 kV | Up to 5,000 kVA | 50 / 60 Hz | ONAN / ONAF | View product — 20 kV Three Phase Oil-Immersed Distribution Transformer |
| Up to 44 kV Unit Substation Transformer | Up to 44 kV | Up to 10,000 kVA | 50 / 60 Hz | ONAN / ONAF / KNAN / KNAF | View product — Up to 44 kV Unit Substation Transformer |
| 35 kV Three Phase Oil-Immersed Power Transformer | 35 kV | Up to 100,000 kVA | 50 / 60 Hz | ONAN / ONAF / KNAN / KNAF | View product — 35 kV Three Phase Oil-Immersed Power Transformer |
| 66 kV Three Phase Oil-Immersed Power Transformer | 66 kV | Up to 100,000 kVA | 50 / 60 Hz | ONAN / ONAF | View product — 66 kV Three Phase Oil-Immersed Power Transformer |
| 110 kV Three Phase Oil-Immersed Power Transformer | 110 kV | Up to 100,000 kVA | 50 / 60 Hz | ONAN / ONAF | View product — 110 kV Three Phase Oil-Immersed Power Transformer |
| 230 kV Three Phase Oil-Immersed Power Transformer | 230 kV | Specified per project | 50 / 60 Hz | ONAN / ONAF / OFAF / ODAF | View product — 230 kV Three Phase Oil-Immersed Power Transformer |
| 500 kV Three Phase Oil-Immersed Power Transformer | 500 kV | Specified per project | 50 / 60 Hz | ONAN / ONAF / OFAF / ODAF | View product — 500 kV Three Phase Oil-Immersed Power Transformer |
Products
Open a platform for the published specifications, configuration options and project review points.
Commercial buildings, hospitals, airports, factories, residential areas, renewable energy projects, data centers.
Industrial distribution, rural networks, utility projects.
Urban areas, commercial buildings, industrial users, renewable integration.
Urban and rural power distribution, industrial facilities, renewable integration, substations, transportation hubs, hospitals, large commercial complexes.
Regional substations, industrial parks, utility grids.
Transmission substations, large-scale renewable collector stations, utility grid projects.
Transmission substations, utility grid interconnections, renewable collector stations and large industrial projects.
EHV transmission substations, utility grid projects, large renewable collector stations and grid interconnection projects.
RELATED ORDER RECORDS
Selected S11-M oil-immersed distribution order records. These examples relate to the 10 kV family, not the entire power-transformer range.
| Order date | Configuration | Voltage ratio | Quantity | Details |
|---|---|---|---|---|
| 2,000 kVAS11-M-2000 · Dyn11 | 10 / 0.4 kV | 1 unit | Enquire similar | |
| 250 kVAS11-M-250 · Dyn11 | 10 / 0.4 kV | 1 unit | Enquire similar | |
| 500 kVAS11-M-500 · Dyn11 | 10 / 0.4 kV | 1 unit | Enquire similar |
Contract/order records, not stock or delivery confirmations. Specifications vary by project.
BEFORE YOU ENQUIRE
Share the details you have. A short description is enough to begin; drawings and specifications can follow.
Request a QuotePrimary and secondary voltage, capacity, frequency, load profile and tap requirements.
Outdoor conditions, containment, access, transport dimensions and the equipment interfaces.
Required standard, loss and noise limits, inspection points and the reports to be reviewed.
Use the system role, voltage and load requirements first. The product groups help shortlist a platform; the approved project datasheet defines its final ratings.
No. The examples shown are 10 kV S11-M distribution order records. They do not establish delivery or performance of other products.
Yes. Describe the equipment or project you need to supply. Add the site country and any known voltage, capacity or drawing; our team can help identify the missing information.
Talk to an engineer
A short description is enough. We’ll help clarify the specifications.