Connections
Start with the network voltages and connection arrangement. Review the terminal or cable interfaces against your system and project drawing.
- Primary Voltage
- 66 / 69 kV
- Secondary Voltage
- 6 / 10 / 11 / 33 / 35 kV
Oil Immersed Transformer
An oil-immersed power transformer platform for 66 kV regional substations, industrial parks and utility-grid projects.

Overview
A regional substation enquiry needs both electrical duty and site interfaces. Include the network arrangement, voltage regulation needs and transport constraints when discussing the published platform.

Start with the network voltages and connection arrangement. Review the terminal or cable interfaces against your system and project drawing.
Review the insulating liquid and cooling arrangement for the duty. Confirm the compatible options, installation clearances and liquid containment in the project design.
Plan the footprint, access and cable routes using the approved outline drawing. Share the installation environment so the mechanical interfaces can be reviewed.
Specifications
Listed options describe the product range. Final ratings, compatible combinations and performance are confirmed in the approved project datasheet.
| Capacity range | Up to 100,000 kVA |
|---|---|
| Voltage class | 66 kV |
| Frequency | 50 / 60 Hz |
| Tap Range | ±8 × 1.25% (OLTC) |
| Vector Group | YNd11 |
| Primary Voltage | 66 / 69 kV |
| Secondary Voltage | 6 / 10 / 11 / 33 / 35 kV |
| Cooling | ONAN / ONAF |
|---|---|
| IP class | IP54 |
| Oil type | Mineral oil / FR3 |
| Environment | Outdoor |
| Core material | Cold-rolled grain-oriented silicon steel |
| Insulation class | Class A |
Standards & compliance
GB / IEC / IEEE
Applicable standards and required certificates or test reports must be agreed for the specific project. A standard listed here is not a certification claim.
Listed options describe the product range. Final ratings, compatible combinations and performance are confirmed in the approved project datasheet.
Manufacturing
Explore our manufacturing and test equipment. The production route and acceptance tests are agreed for each configuration.



Images from our factory gallery. Equipment shown does not imply every product uses the same manufacturing process.
Explore the FactoryReview the single-line diagram, insulation levels, fault duty, impedance, tap regulation and protection. Include the access route, foundation and termination arrangement so the installation scope is understood.
Start with your email and a short description. Tell us what you want to power, replace or purchase. You can send known ratings or a drawing, but you do not need to know every specification.
These are defined in the project quotation after reviewing the technical scope, quantity, destination and document requirements.
Talk to an engineer
A short description is enough. We’ll help clarify the specifications.